Incidence of medical device-related pressure injuries and identification of risk factors in the neonatal unit


Yarkıner Z., Bahar A., Sönmez M., Kapan E., ŞAHİN E. B. S., Köstekçi E., ...Daha Fazla

Journal of Tissue Viability, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1016/j.jtv.2024.09.005
  • Dergi Adı: Journal of Tissue Viability
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Social Sciences Citation Index (SSCI), Scopus, CINAHL, MEDLINE
  • Anahtar Kelimeler: Medical device-related pressure injuries, Neonatal intensive care unit, Newborn, Nursing
  • Ankara Üniversitesi Adresli: Evet

Özet

Aim: This study was conducted to investigate the incidence of medical device-related pressure injuries (MDRPIs) and the risk factors influencing their occurrence in the neonatal intensive care unit (NICU). Method: This study is a prospective, descriptive study. The research was conducted with 116 newborns between June 1, 2022, and June 1, 2023. Newborns who stayed in the neonatal intensive care unit for at least 24 h were observed daily for medical device-related pressure injuries under and around each medical device throughout their stay in the intensive care unit. The “Case Report Form,” "MDRPIs Monitoring Form," “Braden Q scale for children,” National Pressure Injury Advisory Panel (NPIAP) Pressure Grading, and Glasgow Coma Scale were used in the research. Results: The incidence of medical device-related pressure injuries is 35.3 % (41/116). It was found that 38.1 % (16/42) of medical device-related pressure injuries developed due to Near-Infrared Spectroscopy (NIRS) probes, and 33.5 % (14/42) developed due to medical devices related to the respiratory system. In terms of anatomical location, 38.1 % occurred on the forehead, and 23.8 % on the arm/leg. The difference between birth weight, gestational age, development of MDRPIs in newborns receiving sedation and inotropes was found to be statistically significant. Regression analysis identified gestational age (p = 0.040, OR = 0.795, 95%CI = [0.632–1.000]) as an independent risk factor for the occurrence of medical device-related pressure injuries. Conclusions: The incidence of medical device-related pressure injuries in newborns was relatively high in this study, with gestational age being the most significant risk factor for MDRPIs formation. It is crucial for neonatal intensive care nurses to consider associated risk factors while providing newborn care and implement appropriate preventive measures to reduce the incidence of MDRPIs.