Northwestern Medical Journal, cilt.3, sa.3, ss.147-155, 2023 (Hakemli Dergi)
Giriş: Bu çalışmanın amacı resiprokasyon ve sürekli rotasyonla kullanılan çeşitli eğelerle kök
kanal preparasyonu sonrası oluşan dentin defektlerini karşılaştırmaktır.
Yöntem: 90 adet çekilmiş insan alt kesici diş kullanıldı. 15 diş prepare edilmeden bırakıldı
ve kalan dişler rastgele 5 deney grubuna (n=15) ayrıldı. Kök kanalları WaveOne (Dentsply
Maillefer, Ballaigues, Switzerland), WaveOne Gold (Dentsply Maillefer, Ballaigues,
Switzerland), Hyflex EDM OneFile (Coltene/Whaledent, Altstätten, Switzerland), ProTaper
Next (Dentsply Maillefer, Ballaigues, Switzerland) ve ProTaper Universal (Dentsply Maillefer,
Ballaigues, Switzerland) döner eğeleri ile prepare edildi. Daha sonra köklerden apeksten
itibaren 3, 6 ve 9 mm’de kesit alındı ve stereomikroskopla değerlendirildi. İstatistiksel analiz
ki-kare ve Fischer’s Exact testi ile gerçekleştirildi. Anlamlılık düzeyi %5 olarak belirlendi.
Bulgular: Preparasyon yapılmayan kontrol grubunda defekt gözlenmedi. Tüm deney
gruplarında özellikle apikal bölgede (3 mm) dentinal defekt gözlendi. WaveOne ve Hyflex
EDM, kontrol grubuna göre daha fazla dentin defekti gösterdi (p<0.05); ancak aralarında
anlamlı bir fark bulunmadı (p>0.05). WaveOne; ProTaper Universal, ProTaper Next ve
WaveOne Gold gruplarından daha fazla dentin defektine neden oldu (p<0.05). Hyflex EDM,
ProTaper Next’den daha fazla defekte neden oldu (p<0.05). Diğer deney grupları arasında
fark yoktu (p>0.05).
Sonuç: Bu çalışmada kullanılan tüm döner eğe sistemleri, hareket kinematiklerinden
bağımsız olarak dentin defektine neden oldu.
Aim: This study aimed to compare dentinal defects after root canal preparation with various
reciprocating and continuous rotary files.
Methods: 90 extracted human mandibular incisor teeth were used. 15 teeth left unprepared
and the remaning teeth were randomly divided into 5 experimental groups (n=15). Root
canals were prepared with WaveOne (Dentsply Maillefer, Ballaigues, Switzerland), WaveOne
Gold (Dentsply Maillefer, Ballaigues, Switzerland), Hyflex EDM OneFile (Coltene/Whaledent,
Altstätten, Switzerland), ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland), and
ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) rotary files. Then roots
were sectioned at 3, 6 and 9 mm from the apex and evaluated with a stereomicroscope.
Statistical analysis was performed with chi-square and Fischer’s Exact test. The significance
level was set at 5%.
Results: No defects were observed in the unprepared control group. Dentin defect were
observed in all the experimental groups, especially in the apical region (3 mm). WaveOne
and Hyflex EDM showed more dentinal defects than the control group (p<0.05); however,
no significant difference was found between them (p>0.05). WaveOne caused significantly
more dentinal defects than the ProTaper Universal, ProTaper Next, and WaveOne Gold
groups (p<0.05). Hyflex EDM caused more defects than ProTaper Next (p<0.05). There was
no difference between the other experimental groups (p>0.05).
Conclusion: All the rotary file systems used in this study caused dentinal defects regardless
of the motion kinematics.
Keywords: Dentinal defect, rotary instrumentation, stereomicroscope