Özet
AIM or PURPOSE
To compare the effects of commonly used intracanal medicaments and root thirds (apical, middle, coronal) on the bond strength of a bioceramic root canal sealer.
MATERIALS and METHODS
Thirty-two single-rooted teeth were prepared to a standardized final apical size using ProTaper Universal to F5 (Dentsply Sirona, USA). They were assigned to four groups (n=8): calcium hydroxide (CH), triple antibiotic paste (TAP), Bio-C Temp (Angelus, Londrina, PR, Brazil), and a control (no medicament). After medicament removal, canals were obturated using a single-cone technique with BioRoot™ Flow (Septodont, Saint-Maur-des-Fossés, France). Roots were sectioned into 1-mm slices from the apical, middle, and coronal thirds (96 specimens). Push-out bond strength (PBS, MPa) was calculated from maximum dislodgement load and bonded area. Failure modes (adhesive/cohesive/mixed) were recorded. Data were analyzed using a mixed-effects model (α=0.05).
RESULTS
No interaction between medicament and root third was detected (p=0.438). Both medicament (p<0.001) and root third (p<0.001) affected PBS. PBS was higher in the apical third than in the coronal (p=0.005) and middle thirds (p<0.001), while middle and coronal thirds were similar (p=0.818). CH showed lower PBS (4.125 MPa) than Bio-C Temp (6.475 MPa; Δ=2.350 MPa, p<0.001) and control (6.230 MPa; Δ=2.105 MPa, p=0.002). Failure modes were similar among medicaments (p=0.998) and root thirds (p=0.317), with cohesive and mixed failures most frequent.
CONCLUSIONS
Both medicament choice and root level influenced bioceramic sealer bond strength. Under these conditions, PBS was highest apically, and CH was associated with lower values, highlighting the importance of medicament selection and root-third variability when interpreting push-out results.