Marginal and internal adaptation and absolute marginal discrepancy of 3D-printed, milled, and prefabricated crowns for primary molar teeth: an in vitro comparative study


AKTAŞ N., AKIN Y., OCAK M., ATABEK D., BANKOĞLU GÜNGÖR M.

BMC Oral Health, cilt.25, sa.1, 2025 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 25 Sayı: 1
  • Basım Tarihi: 2025
  • Doi Numarası: 10.1186/s12903-025-05947-x
  • Dergi Adı: BMC Oral Health
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, MEDLINE, Directory of Open Access Journals
  • Anahtar Kelimeler: 3D-printed crowns, Absolute marginal discrepancy, CAD-CAM restorations, Internal adaptation, Marginal adaptation, Micro-CT analysis, Pediatric dentistry, Prefabricated zirconia crowns, Primary teeth
  • Ankara Üniversitesi Adresli: Evet

Özet

Background: The quality of marginal and internal adaptation plays a crucial role in the clinical longevity of pediatric crowns. This study aimed to evaluate the effect of restoration type (3D-printed, milled, and prefabricated) on the marginal and internal adaptation and absolute marginal discrepancy (AMD) values of crowns for primary molar teeth. Methods: Three restoration groups were created: 3D-printed resin, milled resin-matrix ceramic, and prefabricated zirconia crowns (n = 10 per group). A typodont tooth was prepared according to the guidelines for prefabricated zirconia crowns and scanned to design restorations. 3D-printed and milled crowns were fabricated from the same design. All crowns were cemented on standardized 3D-printed resin dies with self-adhesive resin cement. Marginal and internal adaptation and AMD values were evaluated using micro-computed tomography (micro-CT) at multiple measurement points. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey HSD tests, with statistical significance set at P < 0.05. Results: The restoration type significantly influenced the marginal and internal gap and AMD values (P < 0.05). The prefabricated crown group exhibited the highest marginal gap (233.5 ± 33.4 μm) and internal gap (538.6 ± 47.4 μm). The 3D-printed group showed the highest AMD value (299.5 ± 70.2 μm). The milled group demonstrated the lowest gap values, which remained within clinically acceptable limits. Conclusions: Prefabricated zirconia crowns displayed the highest marginal and internal gaps, whereas milled crowns exhibited the most favorable adaptation values within clinically acceptable limits. Given their superior adaptation, CAD-CAM-produced restorations may be a recommendable alternative for pediatric patients.