Two time steps predictive control application to a bioprocess simulator


Altuntaş S., HAPOĞLU H.

28th European Modeling and Simulation Symposium, EMSS 2016, Larnaka, Kıbrıs (Gkry), 26 - 28 Eylül 2016, ss.162-167 identifier

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Basıldığı Şehir: Larnaka
  • Basıldığı Ülke: Kıbrıs (Gkry)
  • Sayfa Sayıları: ss.162-167
  • Anahtar Kelimeler: Bioprocess simulator, Constant desired pH, PH control, Predictive control
  • Ankara Üniversitesi Adresli: Evet

Özet

The control of batch bioreactors to maintain the pH at a constant set point is quite different from the continuous system applications, because acid and base simultaneous addition has a strong effect on the closed loop performance which may never reach desired value. While it is most desirable to use approximate models based on the chemistry of the system, this may not always be possible for batch bioprocesses. The present paper discusses usage of a simulator with appropriate input and output data obtained from the real batch bioprocess without control. The real process pH behaviour was simulated by using 7M citric acid flowrate changes in the face of constant base addition. Two time steps predictive control was applied to the bioprocess simulator by coordinating 0.5M citric acid and 0.5M sodium bicarbonate flow rates. The best control weighting factor magnitude was determined. The constant set point following was achieved successfully.