Spectral interference corrections for the measurement of U-238 in materials rich in thorium by a high resolution gamma-ray spectrometry


YÜCEL H., Solmaz A. N., Kose E., Bor D.

APPLIED RADIATION AND ISOTOPES, cilt.67, sa.11, ss.2049-2056, 2009 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 67 Sayı: 11
  • Basım Tarihi: 2009
  • Doi Numarası: 10.1016/j.apradiso.2009.07.011
  • Dergi Adı: APPLIED RADIATION AND ISOTOPES
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.2049-2056
  • Anahtar Kelimeler: Uranium (U-238), Thorium (Th-232), gamma-Ray spectrometry, Spectral interference, Self-absorption, True coincidence summing, Correction, URANIUM, RA-226
  • Ankara Üniversitesi Adresli: Evet

Özet

In this study, the spectral interferences are investigated for the analytical peaks at 63.3 keV of Th-234 and 1001.0 keV of Pa-234m, which are often used in the measurement of U-238 activity by the gamma-ray spectrometry. The correction methods are suggested to estimate the net peak areas of the gamma-rays overlapping the analytical peaks, due to the contribution of Th-232 that may not be negligible in materials rich in natural thorium. The activity results for the certified reference materials (CRMs) containing U and Th were measured with a well type Ge detector. The self-absorption and true coincidence-summing (TCS) effects were also taken into account in the measurements. It is found that ignoring the contributions of the interference gamma-rays of Th-232 and U-235 to the mixed peak at 63.3 keV of Th-234 (U-238) leads to the remarkably large systematic influence of 0.8-122% in the measured U-238 activity, but in case of ignoring the contribution of Th-232 via the interference gamma-ray at 1000.7 keV of Ac-228 to the mixed peak at 1001 keV of Pa-234m (U-238) results in relatively smaller systematic influence of 0.05-3%, depending on thorium contents in the samples. The present results showed that the necessary correction for the spectral interferences besides self-absorption and TCS effects is also very important to obtain more accurate U-238 activity results. Additionally, if one ignores the contribution of Th-232 to both U-238 and K-40 activities in materials, the maximum systematic influence on the effective radiation dose is estimated to be similar to 6% and similar to 1% via the analytical peaks at 63.3 and 1001 keV for measurement of the U-238 activity, respectively. (C) 2009 Elsevier Ltd. All rights reserved.