Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, cilt.607, sa.3, ss.554-563, 2009 (SCI-Expanded)
Possibilities of discriminating neutrons and γ rays in the AGATA γ-ray tracking spectrometer have been investigated with the aim of reducing the background due to inelastic scattering of neutrons in the high-purity germanium crystals. This background may become a serious problem especially in experiments with neutron-rich radioactive ion beams. Simulations using the Geant4 toolkit and a tracking program based on the forward tracking algorithm were carried out by emitting neutrons and γ rays from the center of AGATA. Three different methods were developed and tested in order to find "fingerprints" of the neutron interaction points in the detectors. In a simulation with simultaneous emission of six neutrons with energies in the range 1-5 MeV and 10 γ rays with energies between 150 and 1450 keV, the peak-to-background ratio at a γ-ray energy of 1.0 MeV was improved by a factor of 2.4 after neutron rejection with a reduction of the photopeak efficiency at 1.0 MeV of only a factor of 1.25. © 2009 Elsevier B.V. All rights reserved.