Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft


Creative Commons License

Kivovics M., Szabo B. T., Nemeth O., Ivanyi D., Trimmel B., Szmirnova I., ...Daha Fazla

JOURNAL OF CLINICAL MEDICINE, cilt.9, sa.2, 2020 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 9 Sayı: 2
  • Basım Tarihi: 2020
  • Doi Numarası: 10.3390/jcm9020303
  • Dergi Adı: JOURNAL OF CLINICAL MEDICINE
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, EMBASE, Directory of Open Access Journals
  • Anahtar Kelimeler: sinus floor elevation, allograft, cone-beam computed tomography (CBCT), microcomputed tomography (micro-CT), bone quality, volumetric study, 3-year follow up, TOOTH EXTRACTION, ACCURACY, MICROSTRUCTURE, PLACEMENT, IMPLANTS, DENSITY, SITES, CBCT, CT
  • Ankara Üniversitesi Adresli: Evet

Özet

The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 +/- 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman's test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data (p < 0.05). Mean volumetric reduction of 39.28% (11.88-60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability.