Electrochemical evaluation and determination of antiretroviral drug fosamprenavir using boron-doped diamond and glassy carbon electrodes


Gümüştaş M., Özkan S. A.

ANALYTICAL AND BIOANALYTICAL CHEMISTRY, cilt.397, sa.1, ss.189-203, 2010 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 397 Sayı: 1
  • Basım Tarihi: 2010
  • Doi Numarası: 10.1007/s00216-009-3334-3
  • Dergi Adı: ANALYTICAL AND BIOANALYTICAL CHEMISTRY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.189-203
  • Anahtar Kelimeler: Fosamprenavir, Oxidation mechanism, Glassy carbon, Boron-doped diamond, Determination, Voltammetry, HIV-PROTEASE INHIBITORS, PERFORMANCE LIQUID-CHROMATOGRAPHY, ACTIVE METABOLITE M8, HUMAN PLASMA, VOLTAMMETRIC DETERMINATION, AMPRENAVIR, SAQUINAVIR, NELFINAVIR, RITONAVIR, INDINAVIR
  • Ankara Üniversitesi Adresli: Evet

Özet

Fosamprenavir is a pro-drug of the antiretroviral protease inhibitor amprenavir and is oxidizable at solid electrodes. The anodic oxidation behavior of fosamprenavir was investigated using cyclic and linear sweep voltammetry at boron-doped diamond and glassy carbon electrodes. In cyclic voltammetry, depending on pH values, fosamprenavir showed one sharp irreversible oxidation peak or wave depending on the working electrode. The mechanism of the oxidation process was discussed. The voltammetric study of some model compounds allowed elucidation of the possible oxidation mechanism of fosamprenavir. The aim of this study was to determine fosamprenavir levels in pharmaceutical formulations and biological samples by means of electrochemical methods. Using the sharp oxidation response, two voltammetric methods were described for the determination of fosamprenavir by differential pulse and square-wave voltammetry at the boron-doped diamond and glassy carbon electrodes. These two voltammetric techniques are 0.1 M H2SO4 and phosphate buffer at pH 2.0 which allow quantitation over a 4 x 10(-6) to 8 x 10(-5) M range using boron-doped diamond and a 1 x 10(-5) to 1 x 10(-4) M range using glassy carbon electrodes, respectively, in supporting electrolyte. All necessary validation parameters were investigated and calculated. These methods were successfully applied for the analysis of fosamprenavir pharmaceutical dosage forms, human serum and urine samples. The standard addition method was used in biological media using boron-doped diamond electrode. No electroactive interferences from the tablet excipients or endogenous substances from biological material were found. The results were statistically compared with those obtained through an established HPLC-UV technique; no significant differences were found between the voltammetric and HPLC methods.