DEVELOPMENT OF ELECTROCHEMICAL SENSOR BY MOLECULARLY IMPRINTING POLYMER FOR DETECTION OF AN INFLUENZA VIRUS NEURAMINIDASE INHIBITOR PERAMIVIR


Creative Commons License

ÖZÇELİKAY AKYILDIZ G., ÖZKAN S. A.

Ankara Universitesi Eczacilik Fakultesi Dergisi, cilt.48, sa.1, 2023 (Scopus) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 48 Sayı: 1
  • Basım Tarihi: 2023
  • Doi Numarası: 10.33483/jfpau.1348090
  • Dergi Adı: Ankara Universitesi Eczacilik Fakultesi Dergisi
  • Derginin Tarandığı İndeksler: Scopus, Central & Eastern European Academic Source (CEEAS), EMBASE, TR DİZİN (ULAKBİM)
  • Anahtar Kelimeler: Commercial serum sample, determination, electrochemical sensor, molecularly imprinted polymer, peramivir
  • Ankara Üniversitesi Adresli: Evet

Özet

Objective: Influenza viruses are the most common cause of influenza. Antiviral drugs prevent the spread of the virus through the infected cells. Peramivir is one of the antiviral drugs that is an inhibitor of influenza virus neuraminidase. In our study, we aimed to develop a MIP-based electrochemical sensor to determine Peramivir. This study is the first to create an electrochemical sensor for Peramivir. MIP(PERA)/GCE was fabricated with the electropolymerization of 4-aminophenol (4-AP) and ortophenilendiamine (o-PD) in the presence of Peramivir. The developed MIP(PERA)/GCE was applied to the commercial serum sample for analysis of Peramivir. Material and Method: PERA is supplied by Tobio Novelpharma pharmaceutical company (Istanbul, Türkiye). Potassium ferricyanide ([K3Fe(CN)6]), potassium ferrocyanide (K4[Fe(CN)6].3H2O), and potassium chloride (KCl), 4-aminophenol (4-AP) and ortophenilendiamine (o-PD), commercial human serum sample, dopamine, ascorbic acid, uric acid, paracetamol, KNO3, Na2SO4 ve MgCl2 were obtained from Sigma-Aldrich (St. Louis, Missouri, USA). Methanol, acetic acid, oxalic acid, hydrochloric acid, acetonitrile, sodium hydroxide, and ethanol were purchased by Merck. The redox process was investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) by the Dropsens μStat 400 Bipotantiostat/ Galvanostat (Metrohm, Herisau, Switzerland). Three-electrode systems consisted of a glassy carbon working electrode (GCE, 3mm2, BASi, USA), a saturated Ag/AgCl reference electrode, and a Pt wire. Result and Discussion: The sensor exhibits a linear range of 1-10 pM with a detection limit of 0.158 pM. The MIP(PERA)/GCE sensor could detect PERA from commercial serum samples with a high recovery of 101.81%.