Results of the oxygen Fick method in a closed blood circulation model including "total arteriovenous diffusive shunt of oxygen"


Ozbek M., Akay A.

THEORY IN BIOSCIENCES, cilt.123, sa.2, ss.111-123, 2004 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 123 Sayı: 2
  • Basım Tarihi: 2004
  • Doi Numarası: 10.1016/j.thbio.2003.09.001
  • Dergi Adı: THEORY IN BIOSCIENCES
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.111-123
  • Anahtar Kelimeler: computer modeling, diffusion, oxygen uptake, oxygen release, mixed compartment, closed circulation, arteriovenous diffusive shunt, INDIRECT CALORIMETRY, CARDIAC-OUTPUT, INTENSIVE-CARE, CONSUMPTION, PRINCIPLE, EXCHANGE, MUSCLE, PO2
  • Ankara Üniversitesi Adresli: Hayır

Özet

It is considered that arteriovenous diffusive shunts of oxygen may cause inaccuracy of the oxygen Fick method as UpVO(2) > Q(CaO2 - CvO(2)) where UpVO(2) is the pulmonary oxygen uptake, Q is the cardiac output, and CaO2 and CvO(2) are the arterial and venous oxygen contents, respectively.