Acute pulmonary oedema during cardiac resynchronization therapy device implantation: management with the activation of intra-aortic balloon pump


Creative Commons License

Altin T., CANDEMİR B., Ozkaramanli D., AKYÜREK Ö., Karaoguz R., Guldal M.

EUROPACE, vol.10, no.10, pp.1232-1234, 2008 (SCI-Expanded) identifier identifier identifier

  • Publication Type: Article / Article
  • Volume: 10 Issue: 10
  • Publication Date: 2008
  • Doi Number: 10.1093/europace/eun171
  • Journal Name: EUROPACE
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.1232-1234
  • Ankara University Affiliated: Yes

Abstract

In this report, we present the case of two patients who experienced the development of acute pulmonary oedema during biventricular pacemaker implantation for cardiac resynchronization therapy. In both the cases, the activation of an intra-aortic balloon pump improved the clinical condition and the operation could be completed, which would otherwise have to be postponed.