Chemometric optimization and validation of an LC-MS/MS method for PEth determination in dried saliva spots: A green and non-invasive approach
Microchemical Journal, cilt.230, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 230
- Basım Tarihi: 2026
- Doi Numarası: 10.1016/j.microc.2026.119884
- Dergi Adı: Microchemical Journal
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, BIOSIS, Chemical Abstracts Core, Chimica, Index Islamicus, Academic Search Ultimate (EBSCO), Engineering Source (EBSCO)
- Anahtar Kelimeler: Alcohol biomarker, Chemometric optimization, Dried saliva spot, Green analytical chemistry, LC-MS/MS, Phosphatidylethanol
- Ankara Üniversitesi Adresli: Evet
Özet
Phosphatidylethanol (PEth) is an established direct biomarker of alcohol exposure, but its routine determination relies predominantly on blood-based matrices. This study aimed to develop and analytically evaluate a miniaturized LC-MS/MS method for PEth 16:0/18:1 and PEth 16:0/18:2 in dried saliva spots (DSS), and evaluate its application to paired authentic DSS and dried blood spot (DBS) specimens. Sample-preparation variables were screened using a Plackett–Burman design and subsequently optimized by central composite design. Sample volume was the dominant determinant of analytical response for both homologues, and the quadratic models showed high explanatory performance (R2 = 0.9801 and 0.9767) with non-significant lack of fit. A practical operating condition of 10 μL saliva, 275 μL of 10% isopropanol in acetonitrile, and evaporation at 37 °C was selected. Quadratic calibration was used for both PEth 16:0/18:1 and PEth 16:0/18:2 (R2 = 0.99222 and 0.99380, respectively). The LODs were 0.87 and 0.91 ng/mL and the signal-based LOQs were 3.00 and 3.08 ng/mL for PEth 16:0/18:1 and PEth 16:0/18:2, respectively. PEth 16:0/18:1 met the predefined accuracy and precision criteria, whereas PEth 16:0/18:2, evaluated as a complementary homologue, exceeded the precision criterion at the low and high QC levels. Extraction recoveries ranged from 93.97% to 110.76%, although substantial matrix effects and limited ambient stability were observed. In 16 paired authentic samples, both homologues were detected in all DBS specimens, whereas PEth 16:0/18:1 and PEth 16:0/18:2 were detected in 5/16 and 6/16 DSS specimens, respectively. The complete DSS workflow yielded an AGREE score of 0.70. DSS therefore provides a feasible non-invasive matrix for PEth analysis, but matrix-specific limitations currently preclude direct transfer of blood-based interpretive criteria.